Xcos: did not halt simulation on the 2nd diagram tab close 54/10554/3
Clément DAVID [Thu, 21 Feb 2013 07:09:34 +0000 (08:09 +0100)]
Bug #8600 fixed bis correction, the simulation halted even if this not the
last opened Xcos diagram.

Change-Id: I67930012c21f6829c837d22adf2c4e8ea2c38ac3

scilab/modules/xcos/src/java/org/scilab/modules/xcos/Xcos.java

index abf4743..2db3c68 100644 (file)
@@ -621,7 +621,7 @@ public final class Xcos {
             diagrams.remove(f);
         }
 
-        if (openedDiagrams().size() <= 1) {
+        if (openedDiagrams().size() <= 0) {
             /* halt scicos (stop the simulation) */
             InterpreterManagement.requestScilabExec("if isdef('haltscicos'), haltscicos(), end;");
         }